Device Family: Intel® Stratix® 10

Intel Software: Quartus Prime Pro

Type: Errata

Area: Intellectual Property


Last Modified: March 16, 2020
Version Found: v19.3
Version Fixed: v19.4
Bug ID: 1507807907
IP: 25G Ethernet, CPRI

Why does the E-tile Hard IP Intel® Stratix® 10 25G Ethernet to CPRI Dynamic Reconfiguration Design Example Modelsim simulation run never end ?

Description

Due to a problem in the Intel® Quartus® Prime Pro Edition version 19.3 Software, the design example Modelsim simulation run will get stuck at the last stage of dynamic reconfiguration operation and not complete the simulation.

  • # INFO: Starting dynamic reconfiguration: 2.4G CPRI --> 25G+PTP+RSFEC 

Workaround/Fix

This problem is fixed starting with the Intel® Quartus® Prime Pro Edition version 19.4 software