Device Family: Intel® Stratix® 10, Intel® Stratix® 10 DX, Intel® Stratix® 10 MX, Intel® Stratix® 10 TX

Intel Software: Quartus Prime Pro

Type: Answers

Area: Intellectual Property


Last Modified: January 17, 2020
Version Found: v19.2
Version Fixed: v19.3
Bug ID: 1409630957
IP: ethernet, Ethernet 10G MAC, 25G Ethernet

Why do the design examples for the Intel® Stratix® 10 E-Tile Hard IP for Ethernet - 10Gbps and 25Gbps variants send an incorrect number of packets?

Description

When using the Intel® Quartus® Prime Pro Edition Software version 19.2 or earlier, when creating a design example with the Intel® Stratix® 10 E-Tile Hard IP for Ethernet - 10Gbps and 25Gbps base variants, operating in fixed and incremental modes send an incorrect number of packets. 

Workaround/Fix

To work around this problem in the Intel® Quartus® Prime Pro Edition Software version 19.2 or earlier, stop the running project and restart the device.

This problem has been fixed starting in the Intel® Quartus® Prime Pro edition software version 19.3.