Simulation of the Intel® Stratix® 10 JESD204B example design generated in Intel® Quartus® Prime software version 17.1.1 or earlier may fail when simulating at a resolution of 1ps usng ModelSim SE version 10.5c.
Device Family: Intel® Stratix® 10
Intel Software: Quartus Prime Pro
Type: Answers
Area: Intellectual Property
Last Modified: December 20, 2017
Version Found: v17.0
Bug ID: FB: 500510;
IP: JESD204B
Why does simulation of the Stratix 10 JESD204B IP Example Design fail when using ModelSim SE version 10.5c?
Description
Workaround/Fix
To work around this problem, remove the 1ps resolution from the vsim command line by removing '-t ps' from the vsim command in the modelsim do file msim_setup.tcl.