Device Family: Intel® Stratix® 10, Intel® Stratix® 10 GX

Type: Answers, Errata

Area: Intellectual Property


Last Modified: November 29, 2017
Version Found: v17.1
Bug ID: FB: 495144;
IP: interlaken, 100G Interlaken, 50G Interlaken

Why do I see Board Selection Out of Range, when using the Stratix 10 Interlaken IP Core?

Description

When using the Intel® Stratix® 10 Interlaken IP Core (2nd Generation), you will see the error "Select Board (BOARD_SELECTION) 1 is out of range: No Development Kit", if the project device part is different to that on the dev it, and "Select Board" parameter is set to "Stratix 10 GX Signal Integrity Development Kit".

The device fitted to the Stratix 10 GX Signal Integrity Development kit is the 1SG280HU2F50E2VGS1.

Workaround/Fix

To work around this problem, ensure your project device is set to that on the Stratix 10 GX Signal Integrity Kit(1SG280HU2F50E2VGS1), or set "Select Board" to "No Development Kit".

This problem is scheduled to be fixed in a future release of the Intel Quartus® Prime Pro software.