Device Family: Intel® Arria® 10, Arria® V GZ, Stratix® V GS, Stratix® V GT, Stratix® V GX

Type: Errata

Area: Intellectual Property


Last Modified: April 05, 2017
Version Found: v15.0
Version Fixed: v17.0
Bug ID: FB: 446699;
IP: Arria 10 SerialLite III Streaming, SerialLite III Streaming

Seriallite III example design nios2-bsp: error Can't find SOPC design in ../ directory

Description

When you run the script batch_script.sh on Seriallite_iii example design, you may see this error:

Error: "nios2-bsp: Can't find SOPC design file in ../ directory.".

Workaround/Fix

To work around this problem:

Open the "batch_scripts.sh" using text editor, replace line "SOPC_DIR=../" with "SOPC_DIR=../../ed_synth/demo_control.sopcinfo"