Device Family: Intel® Stratix® 10 MX, Intel® Stratix® 10 TX

Type: Answers

Area: HSIO


Last Modified: Tue Mar 19 2019 11:43:56 GMT-0700
Version Found: v19.1
Version Fixed: v19.3
Bug ID: 1409132014

Error (19104): "S10_fit_error/altera_xcvr_native_s10_etile_191/synth/S10_fit_error_ip_parameters_wbuqy4a.tcl" cannot be found in the Quartus project database files. Please ensure the missing source file is listed as an SDC_ENTITY_FILE or TCL_ENTITY_FILE assignment in the Quartus Settings File (.qsf). 

Description

Due to a problem in the Intel® Quartus® Prime software versions 19.1, you may see the above error when selecting “Enable Multiple Dynamic Reconfiguration Profiles” and not selecting “Enable Dynamic Reconfiguration” in the Intel Stratix® 10 E-tile Transceiver Native PHY IP.

Workaround/Fix

To work around this problem, you should select “Enable Dynamic Reconfiguration” and “Enable Multiple Dynamic Reconfiguration Profiles” in the Intel Stratix 10 E-tile Native PHY IP GUI.