Device Family: Intel® Stratix® 10 TX

Intel Software: Quartus Prime Pro

Type: Answers

Area: HSIO


Last Modified: November 06, 2018
Version Found: v18.0
Bug ID: FB: 595453;

Why do I see error messages when launching Intel Quartus® Prime Pro software version 18.0 Transceiver Toolkit with Intel® Stratix® 10 TX E-tile design ?

Description

The following error messages may be seen in the Intel® Quartus® Prime Pro software version 18.0 when you use transceiver toolkit and load design for Intel® Stratix® 10 TX E-tile device. 

  • Failed to query line encoding
  • Failed to access soft registers
  • Failed to query firmware version

 

Workaround/Fix

To avoid this error message, the reconfig_clk for transceiver PHY IP should be a free running clock. Otherwise, you may encounter the error.