Device Family: Intel® Stratix® 10 MX

Intel Software: Quartus Prime Pro

Type: Answers

Area: EMIF


Last Modified: July 21, 2020
Version Found: v19.1
Bug ID: 1508184108
IP: Stratix 10 External Memory Interfaces

Can the Intel® Stratix® 10 HBM2 efficiency monitor test pattern run in an infinite loop?

Description

The efficiency monitor test pattern is implemented to run only one loop regardless of the traffic generator parameter setting.

 

Workaround/Fix

To make the test pattern run continuously, toggle the wmcrst_n_in signal after the traffic_gen_pass signal is asserted high.