Device Family: Intel® Agilex™

Intel Software: Quartus Prime Pro

Type: Answers

Area: EMIF


Version Found: v20.1
Bug ID: 14011314466
IP: External Memory Interfaces Debug Component

Can the Intel® Agilex® EMIF Debug Toolkit support interfaces in two different I/O rows?

Description

Due to a problem in the Intel® Quartus® Prime Pro Edition Software version 20.1, the Intel Agilex® EMIF Debug Toolkit cannot support interfaces in two different I/O rows since it cannot distinguish between interfaces with the same ID which are in different rows. In an Intel Agilex EMIF design, the ID cannot be set manually.

Note: The Intel Agilex EMIF Debug Toolkit can support multiple interfaces in one I/O row.

Workaround/Fix

To work around this problem in the Intel® Quartus® Prime Pro Edition Software version 20.1, enable the Intel Agilex® EMIF Debug Toolkit on interfaces implemented in one I/O row at a time.

This problem is planned to be fixed in a future release of the Intel Quartus Prime Pro Edition Software.