Device Family: Intel® Stratix® 10

Intel Software: Quartus Prime Pro

Type: Answers, Errata

Area: EMIF


Version Found: v20.2
Version Fixed: v20.3
Bug ID: 14011794330
IP: Stratix 10 External Memory Interfaces

Why do the debug toolkits print additional debug messages or stop printing messages in other cases?

Description

Due to problems in the Intel® Quartus® Prime Pro Edition Software version 20.2, the debug toolkits (for example, the Intel Stratix® 10 EMIF Unified Calibration Debug Toolkit) may print additional debug messages (including duplicate messages) which can be ignored. In other cases, the debug toolkits may print messages but then stop printing messages if the same design changes.

Workaround/Fix

To work around these problems in the Intel® Quartus® Prime Pro Edition Software version 20.2, download Intel Quartus Prime Pro Edition Software version 20.2 patch 0.25. You must install the Intel Quartus Prime Pro Edition Software version 20.2 prior to installing this patch.

> Download the version 20.2 patch 0.25 for Windows (.exe)

> Download the version 20.2 patch 0.25 for Linux (.tar)

> Download the Readme for the Intel Quartus Prime Pro Edition Software version 20.2 patch 0.25 (.txt)