Device Family: Intel® Stratix® 10

Intel Software: Quartus Prime Pro

Type: How-To

Area: Component


Last Modified: October 06, 2020
Version Found: v18.1
Bug ID: 2205691135
IP: Altera OCT

Why is there a  ~bp appended to the end of the RZQ name when used with a RZQ_GROUP assignment? 

Description

When instantiating an RZQ_GROUP assignment to the input RZQ pin name, the Intel® Quartus® Prime Software changes the input RZQ pin name by appending a ~bp.

Workaround/Fix

To work around this problem, change the assignment

from

set_location_assignment -name <input pin name>  -to <pin#>

to

set_location_assignment -name <input pin name>~bp to <pin#>

 

This is scheduled to be fixed in a future release of the Intel® Quartus® Prime Software.