Description

When using the External Memory Interface (EMIF) Toolkit in the Intel® Quartus® Prime Software version 19.1 or later, you may see this error message if you try to run the Create Memory Interface Connection command.

Workaround/Fix

To work around this error message, verify that the Intel® Quartus® Prime Software project contains the .qsf, .qpf, and .sof files in the working directory.

These files are the minimum file set to run the EMIF Toolkit.