Device Family: Stratix® IV

Intel Software: Quartus II, Quartus Prime Standard

Type: Answers

Area: EMIF


IP: DDR2 SDRAM Controller with UniPHY

Error: Cannot find sequencer.elf

Description

When using Windows 10 and generating the Intel® Stratix® IV UniPHY DDR2 IP in the Intel Quartus® Prime Platform Designer, you may see a similar error as shown below.

Error: Cannot find sequencer.elf

 

This error may be due to a conflict when the Windows Subsystem for Linux is enabled in Windows 10.

Workaround/Fix

 

In the Windows Control Panel > Programs > Programs And Features > Turn Windows features on or off,  unselect the parameter : Windows Subsystem for Linux.

Reboot the PC, open the Intel Quartus Prime project and regenerate the UniPHY DDR2 IP.