Article ID: 000086630 Content Type: Troubleshooting Last Reviewed: 03/30/2021

Why does the Intel® Stratix® 10 device failed to configure with the RSU application image?

Environment

  • Intel® Quartus® Prime Pro Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    You may observe "Error code:  0xF004C002" in SDM Debug Toolkit while performing Remote System Update (RSU) to an application image compiled in Intel® Quartus® Prime Pro Edition software version 21.1 with a decision firmware compiled in version prior to 21.1.

    Resolution

    To work around this issue, there are 2 options to update the decision firmware in flash:

     

    a. Update decision firmware Factory image

    quartus_pfg –c <input.sof> <output.rpd> -o mode=ASx4 rsu_upgrade=ON

    OR

    b. Update decision firmware only

    quartus_pfg –c <input.sof> <output.rpd> -o mode=ASx4 rsu_upgrade=ON –o firmware_only=1

     

    For detailed guideline of updating the decision firmware and Factory image, refer to Intel® Stratix® 10 Configuration User Guide or Intel® Stratix® 10 Hard Processor System Remote System Update  User Guide.

    Related Products

    This article applies to 6 products

    Intel® Stratix® 10 MX FPGA
    Intel® Stratix® 10 TX FPGA
    Intel® Stratix® 10 DX FPGA
    Intel® Stratix® 10 GX FPGA
    Intel® Stratix® 10 NX FPGA
    Intel® Stratix® 10 SX SoC FPGA