Due to the Power Management Controller on the Intel® Stratix® 10 Signal Integrity Production Development Kit being a LTM2987 instead of LTM4677, you may see the below error while configuring the Intel Stratix 10 device with a recompiled example design from the development kit installer, that may have the PMBus slave device incorrectly set as LTM4677.
Device has stopped receiving configuration data
Error message received from device : Detected hardware access error. There is a failure in accessing external hardware. (Subcode 0x0033, Info 0x00000000, Location 0x0000C000)