How do I configure the Intel® Quartus® Prime Pro software to use an Intel Enpirion® EM22x device as a SmartVID Power Management Controller for Intel Stratix® 10 devices?

Description

Intel® Enpirion® EM2260 / EM22xx parts can be used as Power Management Controllers for SmartVID enabled variants of Intel Stratix® 10 devices. Follow the instructions below to configure the Intel Quartus® Prime Pro software for this use case.

Workaround/Fix

In the Device and Pin Options dialog box in Intel Quartus Prime Pro Software, under Power management and VID tab select :

  • Bus Speed mode : 100 KHz / 400 KHz
  • Slave Device type : Other
  • PMbus Device X Slave address : Set the PMbus address in hex without the '0x' prefix
  • Voltage Output format : Linear
    • Intel Enpirion devices only support Linear mode
    • If Auto Discovery is selected, set the direct coefficients m/b/r to 0
  • Linear format N : -13
  • Translated voltage value unit : Volts
  • Enable PAGE command : Leave this disabled (Default) 