Article ID: 000074933 Content Type: Error Messages Last Reviewed: 02/10/2023

Error : Device has stopped receiving configuration data

Environment

  • Intel® Quartus® Prime Pro Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    You may see this error message in the Intel® Quartus® Prime Pro Programmer versions 18.1 or later when configuring Intel Stratix® 10 FPGAs with a design where 3V IO is used, but the respective transceiver tile is not powered up.

     

    The full error message is :

    Error: Device has stopped receiving configuration data 

    Error message received from device : Device is in configuration state

    Operation failed

     

     

     

    Resolution

    To avoid this error and to enable 3V IOs in a design targeting any variant of Intel Stratix® 10 FPGAs, power up the VCCR_GXB and VCCH_GXB rails of the respective transceiver tile as per the Intel Stratix 10 Device Family Pin Connection Guidelines.

    Related Products

    This article applies to 1 products

    Intel® Stratix® 10 FPGAs and SoC FPGAs