Due to a problem with the Early Power Estimator (EPE) Intel® Stratix® 10 version 19.2 and earlier, you may see this error even if the total number of used pins in IO tab is within the maximum GPIOs.
Device Family: Intel® Stratix® 10
Type: Answers
Area: Component, Tools
Last Modified: July 23, 2019
Version Found: v19.2
Bug ID: 1507278144
Errors ():Could not allocate the following pins to any bank: - pins at mV" in the Early Power Estimator Intel® Stratix® 10
Description
Workaround/Fix
You can ignore the error and this problem won’t affect your power estimation result.
You can see the correct maximum GPIOs in the respective Intel Stratix 10 product family overview below.
- Intel Stratix 10 GX/SX Product Family Overview - Intel Stratix 10 FPGA and SoC Family Plan
- Intel Stratix 10 TX Product Overview - Intel Stratix 10 TX Family Plan
- Intel Stratix 10 MX (DRAM System-in-Package) Device Overview - Intel Stratix 10 MX Family Plan
This problem will be fixed in future release of the Early Power Estimator Intel Stratix 10.