Device Family: Intel® Stratix® 10

Type: Answers

Area: Component


Last Modified: April 12, 2018
Version Found: v17.1
Bug ID: FB: 544036;

Error(18948): Error message received from device: Detected corrupted configuration data at location 0x00008400

Description

You may encounter this error message during JTAG configuration of Intel® Stratix® 10 devices due to improper PMbus slave mode settings in Intel Quartus® Prime Pro software version 17.1 or earlier. 

Error(18950): Device has stopped receiving configuration data 

Error(18948): Error message received from device: Detected corrupted configuration data at location 0x00008400 

Error(209012): Operation failed 

Workaround/Fix

Refer to Intel® Stratix® 10 Power Management User Guide for the proper PMBus slave mode setting.