Article ID: 000076440 Content Type: Troubleshooting Last Reviewed: 12/21/2022

Is there any known issue with Intel® Stratix® 10 Configuration via Protocol (CvP) operation in Intel® Quartus® Prime Pro Edition Software version 18.1?

Environment

  • Intel® Quartus® Prime Pro Edition
  • BUILT IN - ARTICLE INTRO SECOND COMPONENT
    Description

    You may encounter the following failure when trying to perform Configuration via Protocol (CvP) operation in Intel® Quartus® Prime Pro Edition Software version 18.1:

    • When you perform any Configuration via Protocol operation, there is a small chance that the operation will halt. This issue impacts all Intel Stratix® 10 production devices. 
    • During the Configuration via Protocol (CvP) process, if the bitstream is corrupted after the first 168kB of data, the CVP_CONFIG_ERROR bit in the CvP Status Register goes high. This will cause the Intel Stratix 10 device to hang, and another Configuration cannot recover it via a Protocol (CvP) update. This issue impacts all Intel® Stratix® 10 production devices. 

     

    Resolution

    Power cycle the Intel® Stratix® device to perform the next Configuration via Protocol (CvP) operation.

    Related Products

    This article applies to 1 products

    Intel® Stratix® 10 FPGAs and SoC FPGAs