Description
You may encounter the following failure when trying to perform Configuration via Protocol (CvP) operation in Intel® Quartus® Prime Pro Edition Software version 18.1:
- When you perform any Configuration via Protocol operation, there is a small chance that the operation will halt. This issue impacts all Intel Stratix® 10 production devices.
- During the Configuration via Protocol (CvP) process, if the bitstream is corrupted after the first 168kB of data, the CVP_CONFIG_ERROR bit in the CvP Status Register goes high. This will cause the Intel Stratix 10 device to hang, and another Configuration cannot recover it via a Protocol (CvP) update. This issue impacts all Intel® Stratix® 10 production devices.
Resolution
Power cycle the Intel® Stratix® device to perform the next Configuration via Protocol (CvP) operation.