ID:15391 DSP block output WYSIWYG primitive "<name>" has an ACC_ADDER_OPERATION value set to SUBTRACT, but OPERATION_MODE of DSP block output WYSIWYG primitive "<name>" is set to a value other than ACCUMULATOR or ACCUMULATOR_CHAIN_OUT

CAUSE: The specified DSP block output WYSIWYG primitive has an ACC_ADDER_OPERATION value set to SUBTRACT, but the OPERATION_MODE parameter is set to a value other than ACCUMULATOR or ACCUMULATOR_CHAIN_OUT. The specified DSP block output WYSIWYG primitive must have the OPERATION_MODE parameter set to ACCUMULATOR or ACCUMULATOR_CHAIN_OUT.

ACTION: Set the OPERATION_MODE of the specified WYSIWYG DSP block output primitive to ACCUMULATOR or ACCUMULATOR_CHAIN_OUT, or set the ACC_ADDER_OPERATION value of the specified WYSIWYG DSP block output primitive to ADD.