ID:15373 DSP block multiplier WYSIWYG primitives "<name>" and "<name>" are connected to ports <name> and <name> of the same DSP block output WYSIWYG primitive "<name>"; however, port <name> of DSP block output WYSIWYG primitive is not connected to the same signal source as that of the saturate ports of the DSP block multiplier WYSIWYG primitives

CAUSE: The specified DSP block multiplier WYSIWYG primitives are connected to the specified datain ports of the specified DSP block output WYSIWYG primitive. But, the specified port of the specified DSP block output WYSIWYG primitive is not connected to the same signal source as that of the saturate ports of the DSP block multiplier WYSIWYG primitives. When the specified DSP block multiplier WYSIWYG primitives are connected to the specified ports of the same DSP block output WYSIWYG primitive, the specified port of the DSP block output WYSIWYG primitive must connect to the same signal source of the saturate ports of the DSP block multiplier WYSIWYG primitive.

ACTION: Connect the saturate ports of the DSP block multiplier WYSIWYG primitives to the same signal source of the specified port of the DSP block output WYSIWYG primitive.