ID:15424 DSP block multiplier WYSIWYG primitive "<name>" can only form a scan chain to the same DSP block multiplier WYSIWYG primitive

CAUSE: The specified DSP block multiplier WYSIWYG primitive forms scan chains with different DSP block multiplier WYSIWYG primitives. Scan chains from the specified DSP block multiplier WYSIWYG primitive can only feed the same DSP block multiplier WYSIWYG primitive.

ACTION: Disconnect the specified WYSIWYG DSP block multiplier primitive from the scan chain, or make sure that the SCANOUTA and SCANOUTB port connect to the same WYSIWYG DSP block multiplier primitive.