ID:12477 Transceiver PLL "<name>" drives the xN clock network to non-bonded transmitter channels. The channel span and/or data rate <number> exceeds the xN non-bonded mode beyond transmitter specification

CAUSE: The specified transceiver PLL is using the xN transmitter clock network to feed one or more transmitter channels outside of its transceiver bank beyond the recommended channel span and/or data rate.

ACTION: For data rate violations, use alternate clock network and non-bonding method by changing the transmitter PLL to use x1 clocking to avoid using the xN transmitter clock network. For channel span violations, reduce the number of non-bonded channels to the recommended channel span. For Stratix V, refer to the Stratix V Device Datasheet for the Clock Network Transmitter Specification and Stratix V Device Handbook: Transceiver Clocking chapter for "Data Rates and Spans Supported Using Stratix V Clock Sources and Clock Networks" table. For Arria V GZ, refer to the Arria V GZ Device Datasheet for the Clock Network Transmitter Specification and Arria V GZ Device Handbook: Transceiver Clocking chapter for "Characteristics of x1, x6, and xN Clock Lines for Arria V GZ Devices" table.