ID:16361 DSP block WYSIWYG primitive "<name>" has clear port "clr[<number>]" connected, but you did not specify the clear type -- parameter "clear_type" set to "none". Set the clear_type parameter to either 'aclr' or 'sclr' depending on your design requirements.

CAUSE: The specified DSP block multiplier WYSIWYG primitive has an active clear port but you did not specify the clear type.

ACTION: Change the value of parameter clear_type to either aclr or sclr based on your design requirements.