ID:16041 Invalid enable mode "<name>" for Clock Buffer "<name>" driving PLL "<name>"

CAUSE: The specified clock buffer is not always enabled but drives a PLL. A clock buffer that drives a PLL must always be enabled.

ACTION: Ensure the clock buffer enable mode is set to "always enabled", the enable signal is set to VCC, and/or disconnect the enable input for the clock buffer.