ID:15607 Can't use Auto Open-Drain Pins logic option with input pin "<name>"

CAUSE: You assigned the Auto Open-Drain Pins logic option to the specified input pin. However, you cannot use the Auto Open-Drain Pins logic option when the I/O cell mode is in input mode.

ACTION: To avoid receiving this message in the future, modify the design and change the I/O cell mode to output or bidir mode, or disable the Auto Open-Drain Pins logic option used with the input pin.