ID:12673 Current Strength logic option is set to <text> for pin "<name>", but setting is not allowed with a Termination assignment

CAUSE: You assigned the specified Current Strength logic option setting and a Termination assignment to the specified pin. However, the Current Strength setting is not supported with a Termination assignment for the pin.

ACTION: Remove the Current Strength logic option when using a Termination assignment.