ID:146016 Logic level <number or text> does not match expected logic level <number or text> for node "<name>" at time <time>

CAUSE: You compared the expected versus actual outputs of simulation. The Simulator determined that the first specified logic level does not match the specified expected logic level of the specified node at the specified time. Thus, the simulated output logic level differs functionally from the expected output logic level in the vector source file. This message may occur if the output logic levels in the compiled design do not meet your expectations, or if you have used inappropriate expected output values in the vector source file.

ACTION: You can locate the source of this message to locate the node in the vector source file. You can locate the node in design file(s) to check the design file(s) for functional errors. You will obtain the most reliable functional testing results if the vector source file contains simulation outputs rather than user-defined expected outputs.