ID:17883 To enable the scan chain feature, port SCANIN for DSP block WYSIWYG primitive "<atom name>" must be connected from the SCANOUT port of another DSP block.

CAUSE: The SCANIN port of the specified DSP block WYSIWYG primitive is not connected from the SCANOUT port of another DSP block.

ACTION: Connect the SCANOUT port from the previous DSP block to the SCANIN port of the specified DSP block.