ID:21031 ASYNC_MODE parameter of half-rate input primitive "<name>" must be set to "none" or "preset" when POWER_UP parameter is set to "high"

CAUSE: The ASYNC_MODE parameter of the specified half-rate input primitive is set to an illegal value.

ACTION: Check the design and make sure that the specified parameter values are not in conflict with each other.