ID:12830 The parameter "<parameter value>" of DSP block WYSIWYG primitive "<atom name>" must be set to "NONE" when port <port name> is a constant value or disconnected.
CAUSE: The specified DSP block WYSIWYG primitive has an input or pipeline register used when the signal is constant.
ACTION: Change the specified parameter value to "NONE" to disable the violating register.