ID:15428 DSP block multiplier WYSIWYG primitive "<name>" and DSP block multiplier WYSIWYG primitive "<name>" both use the SCANOUTA register, but adjacent DSP block multiplier WYSIWYG primitives cannot both use the SCANOUTA register when the operation mode is OUTPUT_ONLY

CAUSE: The specified DSP block multiplier WYSIWYG primitive forms a scan chain with the indicated multiplier WYSIWYG primitive and both use the SCANOUTA register. However, the multiplier WYSIWYG primitives cannot both use the SCANOUTA register in the specified OPERATION_MODE.

ACTION: Disconnect one of the specified WYSIWYG DSP block multiplier primitives from the scan chain, or set the CLOCK and CLEAR parameter of the specified register of one of the specified WYSIWYG DSP block multiplier primitives to NONE.