ID:16487 In altera_syncram megafunction, when OPERATION_MODE parameter is set to <value>, total number of bits (width x depth) between port A and port B must be the same

CAUSE: You specified values for port A and port B parameters; however, the total number of bits on side A and side B are not the same. When the OPERATION_MODE parameter is set to the specified value, the port A and port B parameters must be the same. This error usually occurs when you instantiate a megafunction directly in a text file rather than using the IP Parameter Editor.

ACTION: Modify the design and change the port A and port B parameters so that the total number of bits on port A and port B are the same. To avoid receiving this message in the future, Intel recommends using the IP Parameter Editor.