ID:332150 Cannot use the '<Clock Filter Option Name>' option when a clock collection is used for the '<Endpoint Filter Option Name>' option

CAUSE: The specified clock filter option cannot be used when a clock collection is used for the specified endpoint filter option.

ACTION: Do not use the specified clock filter option, or do not use a clock collection for the specified endpoint filter option. If a bare string was used for the endpoint filter, and a clock collection was not desired, explicitly specify a different collection type.