ID:332169 From <Clock Name> to <Clock Name> (<Analysis Type>)

CAUSE: There is no clock uncertainty assignment for these clock to clock transfers.

ACTION: You can use the set_clock_uncertainty command to specify clock uncertainty or you can use the derive_clock_uncertainty command to apply inter-clock, intra-clock, and I/O interface uncertainty assignments based on timing model characterization.