ID:142035 At least one hierarchy in the multi-hierarchy partition "<name>" is assigned to the secured LogicLock region "<name>". This is illegal and will cause an error during Fitting.

CAUSE: You have assigned multi-hierarchy partitions to the specified secured LogicLock region. You cannot assign multi-hierarchy partitions to a secured LogicLock region.

ACTION: Remove the multi-hierarchy partitions assigned to the secured LogicLock region before running the Fitter or a full compilation.