ID:171043 Removed node "<name>" from Logic Lock region "<name>" -- node has a local clock assignment that is incompatible with its Logic Lock region assignment

CAUSE: You assigned the specified node to the specified Logic Lock region. However, the node uses a local clock. A local clock requirement can impose a location constraint that is not compatible with the current Logic Lock region assignment. Click the + icon to expand this message in the Messages window or in the Messages section of the Report window to display details on the individual nodes removed from Logic Lock regions.

ACTION: If you require the node to be assigned to the specified location, assign the node to a custom region. To avoid receiving this message in the future, turn on the Prevent Assignment to Logic Lock Regions logic option for the specified node.