ID:15551 PRESERVE_PLL_COUNTER_ORDER assignment on PLL "<name>" is not honored because PLL_FORCE_OUTPUT_COUNTER assignment on at least one of the output clocks does not permit it

CAUSE: You turned on the Preserve PLL Counter Order logic option assignment on the specified PLL. However, this option is not honored because it is overridden by the PLL Force Output Counter assignment that you have specified on at least one of the output clocks.

ACTION: In order to preserve the counter order, turn off the PLL Force Output Counter logic option on the output clocks.