ID:15063 PLL "<name>" in <name> mode with <name> set to clk[<number>] is not fully compensated because it does not feed a dedicated PLL clock output pin

CAUSE: The specified PLL in the specified mode does not have the specified output clock feeding a dedicated PLL output pin. As a result, the output will not be fully compensated.

ACTION: Connect the output clock to an I/O output pin, or assign the output pin only to a dedicated PLL clock output location. Alternatively, set the PLL to No Compensation mode instead if you do not want compensation.