ID:262001 Signal Tap data acquisition is in <type> state: <text>

CAUSE: You ran the Signal Tap Logic Analyzer. As a result, the data acquisition state changes according to the following sequence: IDLE, FILL, PRE, POST, DONE. In the IDLE state, the Signal Tap Logic Analyzer is ready for data acquisition; in the FILL state, the Signal Tap Logic Analyzer fills the acquired data into the memory buffer; in the PRE state, the Signal Tap Logic Analyzer fills the memory buffer in a circular fashion and waits for the event or trigger to occur; in the POST state, all triggers have occurred and the accompanying text indicates the level of the event; in the DONE state, all samples are collected.

ACTION: No action is required.