ID:15546 PLL output clock "<name>" has PLL_FORCE_OUTPUT_COUNTER assignment forcing use of counter "<name>" for this output clock

CAUSE: You restricted the specified counter to be used for the specified clock output of the specified PLL with the Force PLL Output Counter logic option (that is, the PLL_FORCE_OUTPUT_COUNTER option is used to specify the counter used in the Quartus Prime Settings File (.qsf)).

ACTION: No action is necessary.