ID:16058 PLLs that use the x1 clock network and drive the same HSSI channel must be placed in the same transceiver bank. PLL "<name>" and PLL "<name>" use the x1 clock network and drive the same HSSI channel, however the PLLs are not assigned to the same transceiver bank. In the Assignment Editor, change the location assignment of the second specified PLL to location "<name>" so the two PLLs are in the same transceiver bank.

CAUSE: Your design contains PLLs that use the x1 clock network and drive the same HSSI channel, but the two PLLs are not assigned to the same transceiver bank.

ACTION: Change the PLL location assignment to the specified legal location. You can change PLL location assignments in the Assignment Editor.