ID:176337 Cell <name> fed by <number> non-global control signals -- only <number> control signals may be non-global

CAUSE: The specified cell is fed by the specified number of control signals that are non-global signals. However, the current target device only supports the specified number of non-global control signals.

ACTION: Assign the Global Signal option with a value of Global Clock to one of the clocks, or modify the design so that the cell is driven by less control signals such as clock or asynchronous clear.