ID:16338 WYSIWYG RAM Primitive "<name>" the mixed-port read-during-write must use don't care when operation mode is set to "<name>" .

CAUSE: You have specified an illegal value for mixed port feed through mode in true dual port.

ACTION: Modify the design and set mixed port feed through mode to be "don't care" when it is in true dual port .