ID:64006 WIDTH_MAN_INPUT parameter of the altfp_convert megafunction has value <number>. However, the WIDTH_MAN_INPUT parameter value must be 23 and WIDTH_EXP_INPUT parameter value must be 8 for a single precision floating point format.

CAUSE: You specified a value for the WIDTH_MAN_INPUT parameter of the altfp_convert megafunction. When the WIDTH_MAN_INPUT parameter has the specified value, the altfp_convert megafunction assumes that you want a single precision floating point format, and as such, the WIDTH_MAN_INPUT parameter must be set to 23 and the WIDTH_EXP_INPUT parameter must be set to 8. This error usually occurs when you instantiate a megafunction directly in a text file instead of using the MegaWizard Plug-In Manager .

ACTION: Change the value of the WIDTH_MAN_INPUT parameter to 23 and the value of the WIDTH_EXP_INPUT parameter to 8 of the altfp_convert megafunction for a single precision floating point format.