ID:16485 Cannot use different <clock or clear> ports for <name> port and <name> port in altera_syncram megafunction

CAUSE: You specified different clock or clear ports for the specified ports of the altera_syncram megafunction; however, the specified ports cannot have different clock or clear ports. This error usually occurs when you instantiate a megafunction directly in a text file rather than using the IP Parameter Editor.

ACTION: Modify the design and use the same clock or clear ports for the specified ports. To avoid receiving this message in the future, Intel recommends using the IP Parameter Editor.