ID:14686 WYSIWYG DLL "<name>" has delay chain length of <number>, but the recommended delay chain length in <name> with a <number> MHz clock is <number>. The compiler will use the recommended delay chain length.

CAUSE: The specified WYSIWYG DLL is a legacy DLL targeted for an earlier device family. The configuration of the legacy DLL does not match the recommended configuration in the targeted device family.

ACTION: Intel strongly recommends the use of the ALTMEMPHY Megafunction to implement double data rate memory interfaces.