ID:176519 Placed PLL "<name>" in location <name> PLL feeds the clk port of DLL "<name>"

CAUSE: The Fitter placed the specified phase-locked loop (PLL) in the specified location because the PLL feeds the clk port of the specified delay locked loop (DLL) and must be placed in the specified location to feed the clk port of the DLL.