Retime Stage Reports

The Fitter generates detailed reports showing the results of the Retime stage, including the Retiming Limit Details report. This report lists hold violations for short paths following the Retime stage. The Fitter identifies and corrects the short paths with hold violations during the Fitter (Finalize) stage by adding routing wire along the paths.
Figure 1. Retiming Limit Details